The BORIT® DCU9001 is capable of controlling two
separate doors or a single door (with readers on each side of the door).
This controller is specially designed for access control requirements
in small and mid-sized office building, post office, bank and system
integration's development. For user's convenience, even under some
circumstances without a computer by hand, most operations such as card
library management, password & clock setup, working mode and status
setup can be done manually through connected keypad card reader.
The DCU9001 door controller provides RS232 and RS485 communication ports,
so it can be easily linked to other DCU9001 and work station, a smaller
initial system can grow to secure hundreds of doors. Through the communication
ports, DCU9001 can be upgraded on-line, and to be customized to meets
users' special needs. Door Control Feature ¡ú Controls 2 doors / 2 readers panel
¡ú Supports Wiegand 26, 27, 32, 34, 36 bit card read format
password keyboard card readers
ABA
biometric authentication
proximity IC card ¡ú Input & output:
1 set of wireless alarm input (selectable part).
2 groups standard RJ45 Readers ports
2 standard door statues sensor input ports
2 standard door release button input ports
2 C-type lock relay output port with status LED indicator
(can provide power output 12VDC/2A)
2 C-type auxiliary relay output port with status LED indicator (can
be alarm output) ¡ú Safety protection
all input/output ports have advanced TVS voltage protection
lightening-surge protection
short-circuit protection ¡ú DIP Setup: SW 1-7 for controller address
setup, SW 8 for cold/hot reset ¡ú Communication
1 standard RS232 port, can be directly connected to a computer or
though a modem which enables remote control
1 standard RS485 port ¡ú Capacity and functionalities:
each controller supports 10,000 cardholders and it can be expanded
to 60,000 cardholders
each controller can store 10,000 pieces of info about in & out
records or alarm affairs
2 types of programmable password control: card + 4 digit user code;
card + 4 digit forced code
capable of defining multi time schedule control Technical Specifications
Operating power: 12VDC/500mA
Input parameters: on-off input 0-5V £¬ current<0.3A
Output load : ¨Q 18VAC , working current single line ¨Q 3A,
total ¨Q 5A
Working temperature: -25 ¡æ --55 ¡æ
Working humidity: 20-90%
Reader RJ45 port: 12VDC £¬ current 150mA
Keeping data without power ¡Ý 150days
Size: PCB 130 X 110 X 20mm; mounting board 135 X 115 X 20mm
Case size: 350 X 270 X 75mm
Case materials: metal |
|

|
|