The BORIT® DCU9000 is a powerful and scalable single door controller. It supports 2 readers or keypads and controls both entry and exit (with readers on each side of the door).

DCU9000 can operate off-line, making access control decisions independently from a PC or other controlling device. Its card library management, password setup, working mode and status setup can be done manually through a keypad card reader. It can also be connected to a host computer for system configuration, alarm monitoring and direct control.

DCU9000 is capable to form a system by linking to other DCU9000s (up to 127 units) using an "RS-485" communication bus. DCU9000 is designed for usage at small office and family locations.

Door Control Feature

¡ú Controls single door / 2 readers panel
¡ú Supports Wiegand 26, 27, 32, 34, 36 bit card read format
•  password keypad card readers
•  ABA
•  biometric authentication
•  proximity IC card
¡ú Input & output:
•  2 groups standard RJ45 Readers ports
•  1 standard door input port
•  1 standard door release button input
•  1 C-type lock relay output port with status LED indicator (can provide power output 12VDC)
•  1 C-type auxiliary relay output port with status LED indicator
¡ú Safety protection
•  all inputs/outputs have voltage protection
•  all relay output ports have voltage-surge protection

¡ú 1 standard RS485 communication port
¡ú DIP Setup: SW 1-7 for controller address setup, SW 8 for password keypad setup
¡ú Capacity and Functionalities:
•  each controller supports 60,000 cardholders and 1,000 password users
•  memory: 8K+32K FLASH
•  2 types of programmable password control: card + 4 digit user code; 8 digit super code
•  real-time clock, capable of defining multi alarm control: forced open; door open too long; controller damage, etc

Technical Specifications

•  Operating power: 12VAC/500mA or 15VDC/500mA
•  Input parameters: on-off input 0-5V £¬ current<0.3A
•  Output load parameters : ¡Ü 14VAC or ¡Ü 18VDC, working current ¡Ü 2A
•  Working temperature: -25 ¡æ --55 ¡æ
•  Working humidity: 20-90%
•  Reader RJ45 port: 12VDC £¬ current 150mA
•  EMS memory: 32K+8K FLASH 1MB SRAM
•  Keeping data without power ¡Ý 150days
•  Size: PCB 90X74X20mm; mounting board 240X125X30mm
•  Case size: 240X170X55mm
•  Case material: metal